Up to 200 isolated
channels with multifunction input
The GL800 is fitted with 20 channels as
standard but can be expanded from 20 to 200 channels
with the optional GL800 B-537 and B-538 expansion
modules.
20 Ch
40 Ch
100 Ch
200 Ch
GL800 midi LOGGER unit
1
1
1
1
Channel Expansion base
B-537
--
1
1
1
20Ch Expansion terminal
set B-538
--
1
4
9
A
total of 500 channels can be monitored via the
GL800 software and up to 10 GL800 units can be
networked.
Built-in
flash memory for reliable measurements
The flash memory used for the built-in
memory device ensures that data is retained even
if the power supply is interrupted. This means
momentary disruptions in the AC power supply
or accidentally switching off power will not
result in
data loss. Two ports are provided on the GL800, one for the plug-in USB memory
device and one for connecting to a PC.
Direct
record to a USB memory device
Commercially available USB
memory devices may be used for direct capture
of data.
In
addition, the GL800 can be connect directly
to a PC via the USB cable which allows data
to be transferred or measurements to be stored
directly to the PC.
Capture interval (sampling
speed)
100ms
200ms
500ms
1s
10s
12-MB internal Flash memory
13 hours
1 day & 3
hrs
2 days & 21
hrs
5 days
58 days
256-MB USB memory device
12 days
25 days
62 days
125 days
1256
days
* When 10 channels are
used, all times approximate.
The multifunction GL800 device
accepts inputs from voltage, temperature, current*,
humidity, pulse and logic signals. *External
shunt resistor required.
Voltage:
20 mV to 50 V
Current: 4-20 mA process
signals or larger current with external shunts.
Thermocouples:
K, J, E, T, R, S, B, N, W, (WRe5-26)
RTDs: Pt100, JPt100, Pt1000
(IEC751)
Humidity: 0 to 100%
(The B-530 option is required)
Vivid
145mm(5.7")
TFT color LCD
The bright, easy-to-read
145mm(5.7")
TFT color LCD monitor makes it even easier
to review
measurement parameter settings, measured
waveforms, and digital values.
All
the GL800's functions can be accessed
through the navigation cluster and
LCD screen. Single
touch buttons for such tasks as display
mode, setup and logging start/stop
negate the need
for complicated menu trees.
9 hours of continuous
battery operations
Optional battery packs are available
for use in areas where AC power is unavailable
or subject to interruption. The battery packs
enables 9 hours* of continuous measurement and
provides a remaining battery capacity display
function. * Varies with measurement conditions.
Free
Bundled PC software
The GL800 is bundled
with PC application software that enables
measurements directly to a PC. In addition
to waveform monitoring, this software provides
other useful functions such as direct writing
of data to an Excel file and report creation.
The software also provides a Help display
function for enhanced usability.
Diverse measurement
screens
Various display screens
can be selected: Y-T, X-Y, Digital, Meter,
and Report.
Multi-channel
measurement
One GL800 unit enables
measurement on up to 200 channels at the
device itself, and up to 500 channels when
PC measurement has been specified. In addition,
since the channels can be assigned to four
display groups, they can be arranged according
to the input type.
Convenient functions
A function that displays
the logic alarm status during measurement
and a password protection function are
built in. Other convenient functions are
the display of a CSV file batch conversion
screen after captured data has been replayed
and various data search functions.
Software Features
Configuration and
channel setup via USB or Ethernet Real
time data storage to hard disk.
Stored data import
from GL800.
Email notification
of errors and alarms.
Available measurement
modes: Y-T, X-Y, and FFT.
Separate screens are
available for each of the settings.
Direct Excel
transfer can be enabled as a report
function.
Remote monitoring
via Ethernet; Web server/FTP functions
Your PC’s Firefox,
Opera or Internet Explorer applications
can be used for settings, control, data
monitoring and data acquisition.
The Web server function
enables the acquisition of setting control
data.
The FTP function enables
the acquisition of data stored to the GL800.
GL800
Online - Take an actual GL800 for
a test drive!
GL800 Main Features
20 input channels as
standard, expandable to 200 channels.
Isolated multifunction
channels for Voltage, Temperature or Humidity.
Inputs: Voltage
(20mv to 50V), Thermocouples (K,E,J,T,N,R,S,T,B,W)
and 4-20mA signals via external shunt
resistor. Optional Graphtec Humidity
sensor is available.
Four pulse inputs and
one trigger input.
16-bit ADC resolution.
145mm (5.7") colour
LCD display (320 x 240 pixels).
Waveform and text display
modes.
Easy-to-use keypad
menu system.
Single open-collector
alarm output.
Range of trigger functions.
Real-time statistical
calculation.
Built-in 12Mb memory.
Stores 5.5 million data points.
2 x USB 2.0 interfaces
- one for USB Memory stick and one for
PC connection.
Ethernet (TCP/IP) for
PC connection and WEB/FTP server.
User replaceable batteries
for up to 9 hours of operation.
Scan speed - Maximum.
100 milli Seconds for 1-10 channels.
200 milli Seconds for 11-20 channels.
500 milli Seconds for 21-50 channels.
1 Second for 51-100 channels.
2 Seconds for 101-200 channels.
Stores 5.5 million data
points.
The GL800 includes the
following:
1. GL800 Quick Start
Guide.
2. midi LOGGER Software.
3. Australian mains cable.
4. Power Supply - 24Volts DC.
5. USB Cable*.